{"title":"Fire Alarm Systems","description":"\u003cp style=\"font-size: 1.4em; font-weight: 600; text-align: center; margin-bottom: 1em;\"\u003eCommercial Fire Alarm Panels, Detectors, and Notification Devices\u003c\/p\u003e\n\n\u003cp\u003eFire alarm systems protect commercial buildings with control panels, smoke detectors, heat detectors, carbon monoxide sensors, horn\/strobe notification appliances, pull stations, and annunciators that meet NFPA 72 requirements. The lineup from Potter, System Sensor, FireLite, Silent Knight, and Napco covers conventional and addressable architectures for every building size, all part of the \u003ca href=\"\/collections\/security-surveillance\" title=\"Security \u0026amp; Surveillance\"\u003e\u003cstrong\u003esecurity and surveillance\u003c\/strong\u003e\u003c\/a\u003e catalog.\u003c\/p\u003e\n\n\u003ch2\u003eFire Alarm Systems for Every Environment\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall commercial buildings\u003c\/strong\u003e — conventional fire alarm panels with zone-based detection for offices, retail spaces, and restaurants under 10,000 square feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-story commercial and institutional\u003c\/strong\u003e — addressable systems with point-level device identification for faster troubleshooting across large and complex floor plans\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools and healthcare facilities\u003c\/strong\u003e — dual-action pull stations reducing false alarms in high-traffic areas, combined with code-compliant horn\/strobe notification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouses and industrial spaces\u003c\/strong\u003e — heat detectors and rate-of-rise sensors for environments where dust, fumes, or temperature fluctuations cause false smoke alarms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-building campuses\u003c\/strong\u003e — remote annunciators extending system status visibility to lobbies, guard stations, and fire command centers in separate buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eChoosing the Right Fire Alarm System\u003c\/h2\u003e\n\u003cp\u003eDesigning a fire alarm system starts with the building's occupancy classification, square footage, and authority having jurisdiction (AHJ) requirements. Every component must carry a UL listing matching its intended application, and the overall design must comply with NFPA 72. Potter, FireLite, and Napco panels anchor the system, with System Sensor and Potter notification appliances delivering the audible and visual alerts required by code. Conventional panels group devices into zones, identifying which zone activated but not the specific device. Addressable systems assign a unique address to every device, providing exact identification for faster troubleshooting and maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eConventional vs. Addressable Architecture\u003c\/h3\u003e\n\u003cp\u003eConventional panels are practical and cost-effective for smaller buildings with simple layouts where zone-level identification is sufficient. Addressable systems pay for themselves in larger facilities and multi-story buildings where pinpointing the exact device that triggered speeds response times and reduces diagnostic costs. Addressable modules like Potter's PAD100 series provide point-level identification with single-input, relay, and dual-input options for mapping devices across complex floor plans.\u003c\/p\u003e\n\n\u003ch2\u003eComplete Your Life-Safety Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/door-hardware-exit-devices\" title=\"Door Hardware \u0026amp; Exit Devices\"\u003e\u003cstrong\u003eDoor Hardware and Exit Devices\u003c\/strong\u003e\u003c\/a\u003e — magnetic door holders that release fire doors automatically on alarm activation\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/access-control-systems\" title=\"Access Control Systems\"\u003e\u003cstrong\u003eAccess Control Systems\u003c\/strong\u003e\u003c\/a\u003e — credential readers and access hubs that integrate with fire alarm panels for emergency egress\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/security-cameras\" title=\"Security Cameras\"\u003e\u003cstrong\u003eSecurity Cameras\u003c\/strong\u003e\u003c\/a\u003e — IP cameras providing visual verification of alarm events and evacuation monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/intercoms-door-entry\" title=\"Intercoms \u0026amp; Door Entry\"\u003e\u003cstrong\u003eIntercoms and Door Entry\u003c\/strong\u003e\u003c\/a\u003e — intercom systems for emergency communication during fire events\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"2gig-gb1e-encrypted-glass-break-sensor","title":"2GIG GB1e Glass Break Sensor - Encrypted 345 MHz, 15ft Range, 360-Degree Detection, eSeries Compatible","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eEncrypted 345 MHz Glass Break Sensor with 15ft Detection Range, 360-Degree Horizontal Sensing, Dual Shatter Recognition, Tamper Supervision, and 2GIG eSeries Panel Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe 2GIG GB1e is an encrypted glass break sensor for 2GIG eSeries security panels, including the GC2e and GC3e. Operating on the 345 MHz eSeries encrypted frequency, the GB1e detects the sound of breaking glass within a 15-foot radius using dual shatter recognition technology that analyzes both the initial impact and the sustained sound of glass fracturing. The 360-degree horizontal sensing angle covers an entire room from a single ceiling-mounted or wall-mounted position.\u003c\/p\u003e\n\u003cp\u003eThe encrypted 345 MHz protocol protects sensor signals from interception or replay attacks, and tamper supervision alerts the panel immediately if the sensor housing is opened or removed from its mounting surface. Two built-in test LEDs confirm proper operation during installation and routine maintenance checks. ETL-listed construction and battery-powered operation eliminate the need for dedicated wiring to each sensor location.\u003c\/p\u003e\n\u003ch3\u003eWhere the GB1e Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential properties with ground-floor windows and glass doors\u003c\/strong\u003e where the 15-foot detection radius and 360-degree sensing angle cover an entire room from a single ceiling-mounted sensor, dual shatter recognition reduces false alarms from non-glass impacts, and encrypted communication prevents signal interception in neighborhoods with overlapping security systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial storefronts and retail locations\u003c\/strong\u003e where large glass display windows and entry doors are primary intrusion points, the GB1e adds perimeter detection that triggers before an intruder fully enters the space, and battery-powered wireless installation avoids running new wiring through finished commercial interiors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2GIG eSeries alarm system expansions\u003c\/strong\u003e where existing GC2e or GC3e panels need additional perimeter coverage beyond door and window contacts, the encrypted protocol matches the security level of the rest of the eSeries sensor network, and ceiling or wall mounting adapts to different room layouts without additional hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the GB1e Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncrypted 345 MHz Communication:\u003c\/strong\u003e The eSeries encrypted protocol secures all sensor-to-panel transmissions against interception and replay attacks. Fully supervised operation alerts the panel to low battery, tamper events, and communication loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15-Foot Detection Range with 360-Degree Coverage:\u003c\/strong\u003e A single GB1e covers a 15-foot (4.6 m) radius with 360-degree horizontal sensing, protecting an entire room of glass surfaces from a single mounting point on the ceiling or wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Shatter Recognition Technology:\u003c\/strong\u003e Two-stage acoustic analysis identifies both the initial impact and the sustained breaking pattern of glass, reducing false alarms from non-glass sounds like dropped dishes or nearby construction noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-Powered Wireless Installation:\u003c\/strong\u003e No wiring required from sensor to panel. Battery operation and wireless 345 MHz communication allow placement anywhere within range of the GC2e or GC3e panel without pulling cable through walls or ceilings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow Does a Glass Break Sensor Work?\u003c\/h3\u003e\n\u003cp\u003eGlass break sensors use acoustic detection to identify the specific sound signature of breaking glass. When glass fractures, it produces a distinctive two-part sound pattern: a low-frequency thud from the initial impact followed by high-frequency vibrations as the glass shatters. Dual shatter recognition technology in the GB1e analyzes both components and only triggers an alarm when both are detected in the correct sequence and within the expected frequency range. This two-stage verification is what separates confirmed glass break events from similar sounds like dropped objects, slamming doors, or barking dogs. The 360-degree sensing angle means the microphone responds equally to glass breaking in any direction within its 15-foot radius, so a single sensor can protect multiple windows in the same room.\u003c\/p\u003e","brand":"2GIG","offers":[{"title":"Default Title","offer_id":51134293770424,"sku":"2GIG-GB1E-345","price":69.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-19at9.18.54AM.png?v=1747671546"},{"product_id":"pad300-pcd-addressable-smoke-co-detector","title":"Photoelectric Smoke\/CO Detector PAD300-PCD","description":"\u003cp\u003e\u003cstrong\u003ePAD300-PCD Addressable Smoke \u0026amp; Carbon Monoxide Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PAD300-PCD is a dual-sensor detector designed for use with fire alarm systems using the PAD protocol. It combines advanced photoelectric smoke sensing and electrochemical CO detection in one low-profile device, ensuring reliable protection in life safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e- UL 268 7th Edition photoelectric smoke detection\u003cbr\u003e- UL 2075 carbon monoxide detection\u003cbr\u003e- CO sensor lifespan of 10 years with end-of-life notification\u003cbr\u003e- Wide smoke sensitivity range: 1.1% to 3.5% per foot\u003cbr\u003e- DIP switch addressable — no tools or software needed\u003cbr\u003e- Installs easily into PAD300-series bases with twist-on design\u003cbr\u003e- Walk test and magnetic test switch support\u003cbr\u003e- LED status indicator and built-in dirty detector alert\u003cbr\u003e- UUKL listed for smoke control systems\u003cbr\u003e- Compact form factor under 2\" with base\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eFire safety professionals and system integrators seeking a compact, all-in-one smoke and CO detector that meets the latest UL standards and offers fast, reliable communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This Model:\u003c\/strong\u003e\u003cbr\u003eIt offers long-term CO protection, smart smoke detection with self-monitoring capabilities, and seamless compatibility with PAD-based fire alarm systems—making installation and maintenance simple and efficient.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51196764750008,"sku":"PAD300-PCD","price":160.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-27at1.12.43PM.png?v=1748376778"},{"product_id":"fire-lite-bg-12lx-addressable-pull-station","title":"FireLite BG-12LX Addressable Pull Station","description":"\u003cp\u003e\u003cstrong\u003eFire-Lite BG-12LX Dual-Action Addressable Pull Station\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fire-Lite BG-12LX is a high-performance, dual-action manual pull station designed for addressable Fire-Lite fire alarm control panels (FACPs). Featuring a built-in addressable module, this unit allows precise alarm source identification, helping first responders reach the exact location faster during emergencies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Dual-action design requires two deliberate motions to activate\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Integrated addressable interface for compatibility with Fire-Lite FACPs\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Built-in bicolor LED: flashes during normal operation, latches red in alarm\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e “ACTIVATED” label clearly displays when triggered\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Key reset allows for secure and easy re-arming\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Maintenance access without triggering false alarms\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Captive screw terminals for easy SLC loop wiring\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Surface or semi-flush mounting options\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e ADA-compliant with 5 lb. max activation force\u003cbr\u003e\u003cstrong\u003e✔\u003c\/strong\u003e Textured finish and high-visibility housing for quick identification\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eCommercial, industrial, and institutional fire alarm systems requiring pinpoint manual activation and ADA-compliant features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThe BG-12LX combines Fire-Lite’s trusted addressable technology with a rugged, dual-action pull design—making it a reliable choice for emergency manual activation with clear, visible status feedback.\u003c\/p\u003e","brand":"FireLite","offers":[{"title":"Default Title","offer_id":51198998544568,"sku":"BG-12LX","price":137.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.01.38AM.png?v=1748451775"},{"product_id":"rbvs-retrofit-ball-valve-switch","title":"Potter Retrofit Ball Valve Switch","description":"\u003cp\u003e\u003cstrong\u003eRBVS Retrofit Ball Valve Switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe RBVS is a retrofit switch designed to monitor the open or closed position of ball valves in fire sprinkler systems, as well as the coil position on solenoids used in preaction and deluge systems. Ideal for backflow preventers and trim lines on dry, alarm, and deluge valves, this compact unit reliably detects changes when the valve handle moves from its normal position.\u003c\/p\u003e\n\u003cp\u003eIts spring-loaded actuator makes contact with the valve handle when positioned correctly. If the handle moves, the actuator extends and the internal switch changes state—opening or closing an electrical circuit. This enables fast and accurate detection without tracking the exact angle of the handle or ball.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e✔ Monitors open\/closed status of ball valves\u003cbr\u003e✔ Compatible with solenoid coils on preaction and deluge systems\u003cbr\u003e✔ Spring-loaded plunger actuator for accurate triggering\u003cbr\u003e✔ Detects handle movement without tracking position\u003cbr\u003e✔ Ideal for retrofitting backflow preventers and alarm trim lines\u003cbr\u003e✔ Compact and reliable design for fire protection systems\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eFire safety contractors, inspectors, and building system managers looking for a simple retrofit solution to monitor ball valve status in sprinkler and suppression systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This:\u003c\/strong\u003e\u003cbr\u003eThe RBVS makes it easy to add reliable position monitoring to existing ball valves without major modifications—improving system oversight and safety compliance.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51199008112824,"sku":"RBVS","price":242.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.19.55AM.png?v=1748452955"},{"product_id":"pad100-cd-addressable-co-detector","title":"Potter PAD100-CD Analog Addressable CO Detector","description":"\u003cp\u003e\u003cstrong\u003ePAD100-CD Analog Addressable CO Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PAD100-CD is a reliable, analog addressable carbon monoxide (CO) detector designed for use with fire alarm control panels supporting the Potter Addressable Device (PAD) protocol. It features an advanced electrochemical sensor that delivers accurate CO detection for life safety applications in residential, commercial, and industrial settings.\u003c\/p\u003e\n\u003cp\u003eConstructed with durable, off-white plastic to blend seamlessly with ceiling surfaces, the PAD100-CD offers long-lasting performance and discreet installation. The detector connects via an addressable loop and provides consistent monitoring of hazardous CO levels to help ensure occupant safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e✔ Compatible with PAD protocol fire alarm control panels\u003cbr\u003e✔ Electrochemical sensor for precise CO detection\u003cbr\u003e✔ Designed for life safety applications\u003cbr\u003e✔ Durable off-white housing for low-profile ceiling mounting\u003cbr\u003e✔ Base sold separately\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eFire alarm professionals and system integrators requiring dependable CO detection integrated into an addressable system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose This:\u003c\/strong\u003e\u003cbr\u003eThe PAD100-CD offers the accuracy of an electrochemical sensor with the efficiency of addressable communication, making it a smart choice for scalable fire protection systems.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51199012995256,"sku":"PAD100-CD","price":88.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.30.54AM.png?v=1748453463"},{"product_id":"napco-fw-2s-2-wire-photoelectric-smoke-detector","title":"NAPCO FW-2S 2-Wire Photoelectric Smoke Detector - Low Profile 1.8\", Built-In Sounder, UL Listed, NFPA 72","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eLow-Profile 2-Wire Photoelectric Smoke Detector with Built-In Sounder, Magnetic Test Feature, and NFPA 72 Compliance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe NAPCO FW-2S is a 2-wire photoelectric smoke detector with a built-in sounder that connects directly to conventional \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm systems\u003c\/a\u003e on a single pair of wires. The detector stands just 1.8 inches tall in an ultra-low-profile housing that sits flush against ceilings in finished spaces, and the non-directional smoke chamber eliminates the need to orient the detector toward any particular area during installation. A pulsed LED light source paired with a silicon photodiode receiver provides reliable photoelectric smoke detection, and the built-in sounder delivers local audible notification at the point of detection.\u003c\/p\u003e\n\u003cp\u003eThe FW-2S is designed for \u003ca href=\"\/collections\/napco\"\u003eNAPCO\u003c\/a\u003e fire alarm panels and compatible 2-wire conventional systems where installers need a dependable detector that simplifies both installation and long-term maintenance. The removable smoke labyrinth allows field cleaning without replacing the detector head, the tamper-resistant locking feature prevents unauthorized removal, and the magnetic Go\/No-Go test capability lets technicians verify detector operation during inspections without climbing a ladder with aerosol cans. Automatic sensitivity verification meets NFPA 72 Chapter 7 standards for ongoing compliance.\u003c\/p\u003e\n\u003ch3\u003eWhere the FW-2S Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial office buildings, retail spaces, and hotels\u003c\/strong\u003e where the 1.8-inch low-profile housing blends into finished ceilings without drawing attention, the 2-wire connection minimizes wiring labor on new construction and retrofit projects, and the built-in sounder provides immediate local notification at the point of detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, hospitals, and assisted living facilities\u003c\/strong\u003e where tamper-resistant locking prevents unauthorized removal in high-traffic areas, the magnetic test feature allows inspectors to verify every detector during annual NFPA 72 testing without disrupting occupied spaces, and the removable labyrinth simplifies cleaning on routine maintenance schedules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApartment buildings, condominiums, and multi-family housing\u003c\/strong\u003e where photoelectric detection reduces nuisance alarms from cooking compared to ionization detectors, the non-directional chamber design means the detector works regardless of mounting orientation, and the low-profile housing keeps ceilings clean in residential-grade finishes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the FW-2S Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotoelectric Smoke Detection:\u003c\/strong\u003e Pulsed LED light source with silicon photodiode receiver detects smoke particles through light scattering in a non-directional chamber. Two consecutive high-level signals within a short period trigger the alarm circuitry, reducing false activations from transient conditions. LED indicator remains lit during active alarm for visual confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Wire Operation with Built-In Sounder:\u003c\/strong\u003e Connects to conventional fire alarm panels on a single pair of wires for power, supervision, and alarm signaling. Built-in sounder provides local audible notification at the detector location. Operating voltage range of 8 to 35 VDC accommodates a wide range of panel configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Low 1.8-Inch Profile:\u003c\/strong\u003e Compact housing stands just 1.8 inches from the mounting surface for a flush appearance on finished ceilings. Tamper-resistant locking feature secures the detector to the base and prevents unauthorized removal in public and institutional spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Test and NFPA 72 Compliance:\u003c\/strong\u003e Magnetic Go\/No-Go test allows technicians to verify detector function without aerosol sprays or ladder-mounted tools. Automatic sensitivity window verification meets NFPA 72 Chapter 7 standards for ongoing inspection compliance. Removable smoke labyrinth for field cleaning and maintenance. UL Listed.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NAPCO","offers":[{"title":"Default Title","offer_id":51199016534200,"sku":"FW-2S","price":32.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.37.21AM.png?v=1748453851"},{"product_id":"potter-pad100-psda-addressable-fire-alarm-pull-station","title":"Potter PAD100-PSDA Addressable Fire Alarm Pull Station - Dual Action, Die-Cast Metal, UUKL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDual-Action Addressable Manual Pull Station with Die-Cast Metal Housing, DIP Switch Programming, and Class A\/B\/X SLC Wiring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAD100-PSDA is a dual-action addressable \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm\u003c\/a\u003e pull station built with heavy-duty die-cast metal construction for commercial and institutional installations. The dual-action design requires the operator to lift the front cover before pulling the handle, which reduces false activations in high-traffic areas while maintaining immediate access during a real emergency. DIP switch addressing allows field programming without software tools, and the unit integrates directly with \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e IPA Series panels including the AFC-100, AFC-50, and ARC-100 through SLC wiring in Class A, Class B, or Class X configurations.\u003c\/p\u003e\n\u003cp\u003eOnce activated, the pull handle locks in place and cannot be reset without opening the front cover using the Potter WS-93 key, which matches the same key used on Potter fire alarm control panels for a single-key maintenance workflow. Opening the front cover alone also triggers an alarm, providing tamper protection against unauthorized access. The PAD100-PSDA is UUKL Listed for Smoke Control Systems and mounts in a standard single-gang box at 1.75 x 3.25 x 4.75 inches and 1.46 pounds.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAD100-PSDA Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial office buildings and corporate campuses\u003c\/strong\u003e where the dual-action design prevents accidental activations from passersby and cleaning crews, the die-cast metal housing withstands daily contact in high-traffic hallways and stairwells, and addressable communication reports the exact pull station location to the fire alarm panel for faster emergency response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, hospitals, and institutional facilities\u003c\/strong\u003e where dual-action operation is required by code or preferred by the authority having jurisdiction to reduce nuisance alarms, the WS-93 key reset matches existing Potter panel keys so fire alarm technicians carry a single key for the entire system, and DIP switch programming simplifies addressing during initial installation and future device additions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouses, manufacturing plants, and loading docks\u003c\/strong\u003e where the die-cast metal construction handles industrial environments without cracking or warping, the tamper-triggered alarm on cover opening deters vandalism, and Class A\/B\/X SLC wiring flexibility accommodates the wiring topology required by the facility layout and code requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAD100-PSDA Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Action Activation with Tamper Protection:\u003c\/strong\u003e Requires lifting the front cover before pulling the white T-bar handle to initiate an alarm. Once activated, the handle locks in the pulled position and requires a WS-93 key to reset. Opening the front cover alone triggers an alarm for tamper detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDie-Cast Metal Construction:\u003c\/strong\u003e Heavy-duty die-cast metal housing in red finish resists impact, tampering, and environmental wear in commercial and industrial installations. Dimensions: 1.75 x 3.25 x 4.75 inches. Weight: 1.46 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP Switch Addressable with IPA Panel Compatibility:\u003c\/strong\u003e Field-programmable DIP switch addressing integrates with Potter IPA Series panels including AFC-100, AFC-50, and ARC-100. Supports SLC wiring in Class A, Class B, and Class X configurations for flexible installation topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUUKL Listed for Smoke Control:\u003c\/strong\u003e UL and UUKL Listed for Smoke Control Systems applications. Reset key matches Potter fire alarm control panel key (WS-93) for single-key maintenance across the entire fire alarm system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51199027118264,"sku":"PAD100-PSDA","price":132.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.48.38AM.png?v=1748454529"},{"product_id":"fire-lite-sd365-addressable-commercial-smoke-detector","title":"Fire-Lite SD365 Addressable Photoelectric Commercial Smoke Detector - Intelligent, Walk Test, Interchangeable Bases, UL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eIntelligent Addressable Photoelectric Smoke Detector with Two-Wire SLC Loop, Walk Test with Address Display, and Interchangeable Base System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Fire-Lite SD365 is an intelligent addressable photoelectric \u003ca href=\"\/collections\/fire-alarm-systems\"\u003ecommercial smoke detector\u003c\/a\u003e that connects to the SLC loop on a two-wire circuit with stable, noise-immune communication. The advanced optical sensing chamber detects smoke across a wide range of combustion sources while meeting current code standards for sensitivity performance, and the factory preset 1.5% sensitivity threshold ensures consistent alarm response out of the box. At just 2 inches tall and 6.2 inches in diameter, the low-profile housing mounts flush to ceilings in finished commercial spaces without drawing attention.\u003c\/p\u003e\n\u003cp\u003eThe SD365 is part of the \u003ca href=\"\/collections\/firelite\"\u003eFire-Lite\u003c\/a\u003e intelligent detector family manufactured by Honeywell, and it uses an interchangeable base system that supports photoelectric, ionization, and thermal sensor heads along with optional relay, isolator, and sounder bases. The built-in magnetic test switch and walk-test mode with address display allow technicians to verify every detector on the loop without aerosol cans or panel interaction, and the removable cover with insect-resistant screen simplifies field cleaning. LED indicators blink when the detector is polled by the panel and latch solid during an alarm condition for instant visual identification.\u003c\/p\u003e\n\u003ch3\u003eWhere the SD365 Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffice buildings, corporate campuses, and high-rise towers\u003c\/strong\u003e where addressable detection is required by code for zone identification, the low-profile white housing blends into finished ceilings without impacting interior design, and the interchangeable base system allows future sensor type changes without replacing the detector head or rewiring the SLC loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospitals, schools, and government buildings\u003c\/strong\u003e where walk-test mode with address display lets fire alarm inspectors verify each detector during annual NFPA testing without disrupting occupied spaces, the magnetic test switch eliminates the need for aerosol cans in sensitive environments, and noise-immune SLC communication maintains reliable polling across long wire runs in large facilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHotels, convention centers, and retail complexes\u003c\/strong\u003e where the photoelectric sensing chamber reduces nuisance alarms from kitchen steam and HVAC airflow compared to ionization detectors, the back-pressure sealed design resists false activations from air handling pressure changes, and the removable insect screen prevents contamination in environments where exterior doors open frequently\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the SD365 Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Photoelectric Detection:\u003c\/strong\u003e Advanced optical sensing chamber with factory preset 1.5% sensitivity detects smoke from a wide range of combustion sources. Back-pressure sealed design resists false activations from HVAC pressure differentials. LED blinks when polled, latches solid in alarm for visual status identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Wire Addressable SLC Communication:\u003c\/strong\u003e Connects to the SLC loop on two wires with stable, noise-immune signaling. Low standby current minimizes loop power consumption across large detector counts. Reports individual device address to the fire alarm panel for pinpoint location identification during alarm events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWalk Test with Magnetic Activation:\u003c\/strong\u003e Built-in magnetic test switch activates walk-test mode with address display for field verification. No aerosol cans or panel programming required during inspection. Removable cover and insect-resistant screen for field cleaning and maintenance without replacing the detector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeable Base System:\u003c\/strong\u003e Supports separate bases with SEMS screws for photoelectric, ionization, and thermal sensor interchangeability. Optional relay, isolator, and sounder bases available. Surface mount or electrical box mounting. UL Listed (UL 268, UL 268A, UL 1059). 6.2-inch diameter, 2-inch height, 3.40 oz.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireLite","offers":[{"title":"Default Title","offer_id":51199048319160,"sku":"SD365","price":116.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.58.44AM.png?v=1748455133"},{"product_id":"potter-pad100-dim-addressable-dual-input-module","title":"Potter PAD100-DIM Addressable Dual Input Fire Alarm Module - 2 Class B or 1 Class A, Single SLC Address","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAddressable Dual Input Module That Monitors Two Class B or One Class A Circuit on a Single SLC Loop Address\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAD100-DIM is an addressable dual input \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm module\u003c\/a\u003e that monitors either two Class B initiating device circuits or one Class A circuit while consuming only a single SLC loop address. This allows installers to monitor a paired waterflow switch and valve tamper switch at the same riser location without using two separate addresses on the loop, cutting module counts and simplifying system programming on \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e IPA Series panels. The compact 4.17 x 4.17 x 1.14-inch housing mounts directly to a standard 4-inch square or double gang electrical box.\u003c\/p\u003e\n\u003cp\u003eThe PAD100-DIM uses the PAD protocol for addressable communication on the SLC loop, with a standby current of just 240 microamps to minimize loop power consumption across large systems. A red LED flashes during normal panel polling and blinks rapidly when either input activates, providing instant visual identification during walk testing and alarm events. Each IDC supports up to 100 ohms of wiring resistance and 1 microfarad of capacitance, and a 5.1K ohm end-of-line resistor supervises each circuit. Up to 127 PAD100-DIM modules can be installed on a single SLC loop.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAD100-DIM Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSprinkler riser rooms and valve monitoring stations\u003c\/strong\u003e where a waterflow switch and tamper switch sit within feet of each other at the same riser, the dual input design eliminates the need for two separate monitor modules, and the single SLC address conserves loop capacity for larger systems with hundreds of addressable devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial buildings and high-rise towers\u003c\/strong\u003e where multiple floors each require paired waterflow and tamper monitoring, the compact housing fits inside existing electrical boxes without adding junction boxes, and the 240 microamp standby current keeps total SLC loop current draw manageable across large device counts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouse and industrial facilities\u003c\/strong\u003e where sprinkler zones cover large areas and each zone needs both flow and valve supervision, the Class A and Class B wiring flexibility accommodates the facility wiring topology, and the 32 to 120 degree Fahrenheit operating range handles mechanical room environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAD100-DIM Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Input on a Single Address:\u003c\/strong\u003e Monitors two Class B initiating device circuits or one Class A circuit while using only one SLC loop address. Pairs waterflow and valve tamper switches at a single monitoring point without doubling the module count or consuming additional loop capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Current Addressable Communication:\u003c\/strong\u003e 240 microamp standby and alarm current on the SLC loop minimizes power draw across large systems. PAD protocol communication with red LED status indicator that flashes during polling and blinks rapidly on input activation. Up to 127 modules per SLC loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised IDC Circuits:\u003c\/strong\u003e Each initiating device circuit supports up to 100 ohms of wiring resistance and 1 microfarad of capacitance. 5.1K ohm end-of-line resistor provides continuous circuit supervision. Operating temperature range of 32 to 120 degrees Fahrenheit with humidity tolerance to 93% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Mounting:\u003c\/strong\u003e 4.17 x 4.17 x 1.14-inch housing mounts to a standard 4-inch square or double gang electrical box. 24V DC operating voltage from the SLC loop. Compatible with Potter IPA Series fire alarm panels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51199080595640,"sku":"PAD100-DIM","price":120.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at11.08.42AM.png?v=1748455730"},{"product_id":"system-sensor-pc2rled-l-series-2-wire-led-ceiling-horn-strobe","title":"System Sensor PC2RLED L-Series 2-Wire LED Ceiling Horn Strobe","description":"\u003cp\u003eThe \u003cstrong\u003eSystem Sensor PC2RLED\u003c\/strong\u003e is a ceiling-mount, 2-wire horn strobe featuring energy-efficient LED technology and modern aesthetics. Designed for 24VDC operation only, it is fully compatible with legacy SpectrAlert, SpectrAlert Advance, and L-Series notification appliances. Engineered for simplified installation and reduced power consumption, the PC2RLED is ideal for commercial fire alarm systems requiring effective audio\/visual notification with low current draw.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eReduce power supply costs and improve design flexibility with LED technology that draws less current than traditional Xenon-based units. Enjoy faster installation with plug-in design, universal mounting plate, and built-in shorting spring for pre-install wiring continuity checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eCommercial fire alarm installations, building retrofits, and code-compliant audio\/visual notification applications where compatibility with SpectrAlert systems is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e• 2-wire LED horn strobe for ceiling mounting\u003cbr\u003e• Lower current draw vs. Xenon devices\u003cbr\u003e• Compatible with SpectrAlert, SpectrAlert Advance, and L-Series devices\u003cbr\u003e• 24VDC operation only\u003cbr\u003e• Plug-in mounting with onboard shorting spring\u003cbr\u003e• Rotary switch for tone and volume settings\u003cbr\u003e• Horn rated at 88+ dBA at 16V\u003cbr\u003e• Tamper-resistant design\u003cbr\u003e• Compact, uniform aesthetics across L-Series\u003cbr\u003e• Field-selectable candela settings\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003cbr\u003e• System Sensor PC2RLED Horn Strobe\u003cbr\u003e• Universal Mounting Plate\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This device requires a 24VDC power source and is not compatible with 12V systems.\u003c\/p\u003e\n\u003c!-- Bonus Section (Built-In) --\u003e\n\u003cp\u003e\u003cstrong\u003eHighlights:\u003c\/strong\u003e\u003cbr\u003e• LED = Lower power usage and cost\u003cbr\u003e• Streamlined plug-in install design\u003cbr\u003e• Trusted compatibility with SpectrAlert platforms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQs:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Is this compatible with SpectrAlert Advance devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it's electrically compatible with SpectrAlert, SpectrAlert Advance, and L-Series models.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: What power source is required?\u003c\/strong\u003e\u003cbr\u003eA: This device operates at 24VDC only and is not compatible with 12V systems.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can I test wiring before mounting?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes shorting springs for pre-install continuity testing.\u003c\/p\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":51308410831032,"sku":"PC2RLED","price":81.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-02at4.24.30PM.png?v=1748906698"},{"product_id":"system-sensor-pc2wled-horn-strobe","title":"System Sensor PC2WLED L-Series White Ceiling-Mount 2-Wire Horn Strobe with LED","description":"\u003cp\u003e\u003cstrong\u003eSystem Sensor PC2WLED L-Series White Ceiling-Mount 2-Wire Horn Strobe with LED\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe System Sensor PC2WLED is a white, ceiling-mount LED horn strobe designed to simplify installation and reduce energy usage in modern fire alarm systems. Operating at 24VDC, this 2-wire device integrates plug-in functionality and shorting springs for faster, error-free setup. Compatible with legacy SpectrAlert, SpectrAlert Advance, and all L-Series devices, it ensures smooth integration into both new and retrofit installations.\u003c\/p\u003e\n\u003cp\u003eFeaturing tamper-resistant construction and rotary dials for tone, candela, and volume selection, the PC2WLED is engineered for versatility and code compliance. With LED-based illumination, it draws significantly less current while delivering bright, reliable alerts across multiple environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis device is ideal for professionals seeking reliable notification appliances that reduce NAC power load while maintaining full code compliance. The consistent design across the L-Series simplifies training and inventory management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eCommercial fire alarm systems, schools, hospitals, offices, retrofit upgrades, and energy-conscious installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e- White, ceiling-mount horn strobe\u003cbr\u003e- LED technology for low current draw\u003cbr\u003e- 24VDC operation only\u003cbr\u003e- Compatible with SpectrAlert \u0026amp; L-Series devices\u003cbr\u003e- Plug-in design with shorting springs\u003cbr\u003e- Field-selectable candela settings\u003cbr\u003e- Tone and volume rotary switches\u003cbr\u003e- Tamper-resistant design\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQs:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Is the PC2WLED compatible with older SpectrAlert models?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is fully compatible with SpectrAlert, SpectrAlert Advance, and other L-Series units.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can I adjust the candela and tone settings on-site?\u003c\/strong\u003e\u003cbr\u003eA: Yes, rotary switches allow easy field adjustments without removing the device.\u003c\/p\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":51308414697656,"sku":"PC2WLED","price":77.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-02at4.34.19PM.png?v=1748907264"},{"product_id":"potter-hs-24pwr-wp-outdoor-horn-strobe","title":"Potter HS-24PWR-WP Outdoor Horn Strobe - 75cd, 100dB, Weatherproof, 24VDC Wall Mount, UL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eWeatherproof 24VDC Horn Strobe with 75 Candela Output, 100dB Audible Alert, Selectable Tones, and Low-Profile Outdoor Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter HS-24PWR-WP is a weatherproof outdoor \u003ca href=\"\/collections\/fire-alarm-systems\"\u003ehorn strobe\u003c\/a\u003e that delivers 75 candela of visual notification and 100dB of audible output in a tamperproof low-profile housing built for exterior wall-mount installations. The clear Lexan lens provides full strobe visibility from all angles, selectable tone settings and a high\/low volume switch allow the audible output to be configured for the specific application, and the included WPLPBB low-profile surface-mount back box keeps the installation clean against exterior walls without recessing into the structure.\u003c\/p\u003e\n\u003cp\u003eThe HS-24PWR-WP is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e HS-24 Series and operates on 24VDC from the fire alarm panel notification appliance circuit. The Super-Slide bracket simplifies mounting and alignment, the Checkmate voltage verification feature lets technicians confirm proper wiring before final connection, and AVSM synchronization compatibility ensures all horn strobes on the circuit flash in unison as required by NFPA 72 and ADA standards. The unit is also compatible with Gentex synchronization protocols for mixed-brand notification appliance circuits.\u003c\/p\u003e\n\u003ch3\u003eWhere the HS-24PWR-WP Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding exteriors, loading docks, and covered walkways\u003c\/strong\u003e where fire alarm notification must extend outside the building envelope, the weatherproof and tamperproof housing handles rain, dust, and temperature extremes without degradation, and the 75cd strobe output provides code-compliant visual notification in outdoor ambient light conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParking garages, open-air decks, and outdoor assembly areas\u003c\/strong\u003e where the 100dB audible output cuts through ambient noise from traffic and machinery, selectable tones allow differentiation between fire alarm and other emergency signals, and AVSM synchronization ensures all devices on the notification circuit flash in unison for ADA compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial yards, rooftop mechanical areas, and perimeter locations\u003c\/strong\u003e where the low-profile back box mounts directly to exterior walls without cutting into the structure, the Checkmate voltage verification speeds commissioning across spread-out notification circuits, and the clear Lexan lens maintains full visibility after years of UV and weather exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the HS-24PWR-WP Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e75cd Strobe with 100dB Horn:\u003c\/strong\u003e Fixed 75 candela visual output through a clear Lexan lens for all-angle visibility. 100dB audible output with selectable tones and high\/low volume switch. 24VDC operation from the fire alarm panel notification appliance circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeatherproof and Tamperproof Housing:\u003c\/strong\u003e Red housing with clear Lexan lens rated for outdoor wall-mount installation. Tamperproof construction prevents unauthorized disassembly. Includes WPLPBB low-profile surface-mount back box. Dimensions: 5.8 x 4.8 x 4.2 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronization and Voltage Verification:\u003c\/strong\u003e Compatible with Potter AVSM synchronization modules and Gentex sync protocols for code-compliant simultaneous strobe flash across all devices on the circuit. Checkmate voltage verification confirms proper wiring during commissioning without a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuper-Slide Mounting:\u003c\/strong\u003e Universal 4-inch Super-Slide bracket enables fast, secure mounting and alignment on exterior walls. UL Listed for outdoor fire alarm notification applications. Part of the Potter HS-24 Series.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51308479807672,"sku":"HS-24PWR-WP","price":114.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-02at5.08.27PM.png?v=1748909312"},{"product_id":"system-sensor-p2rled-horn-strobe-led-wall-mount","title":"System Sensor P2RLED L-Series Horn Strobe - LED, 2-Wire, Selectable Candela, 88dBA, 24VDC Wall Mount, Red","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eL-Series LED Horn Strobe with Selectable Candela, Rotary Tone and Volume Control, 2-Wire 24VDC Operation, and SpectrAlert Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe System Sensor P2RLED is an L-Series LED \u003ca href=\"\/collections\/fire-alarm-systems\"\u003ehorn strobe\u003c\/a\u003e that combines audible and visual fire alarm notification in a 2-wire wall-mount package with lower current draw than traditional xenon strobe technology. LED-based strobe output with field-selectable candela settings lets installers configure the visual output for each location without stocking multiple part numbers, and the rotary switches for horn tone and volume provide the same flexibility on the audible side. The P2RLED operates on 24VDC and is electrically compatible with SpectrAlert, SpectrAlert Advance, and all L-Series devices, allowing it to integrate into existing notification appliance circuits without rewiring or protocol changes.\u003c\/p\u003e\n\u003cp\u003eThe L-Series platform is designed for fast installation and reduced commissioning time. The universal plug-in mounting plate includes a built-in shorting spring that maintains circuit continuity while the device is removed, so installers can mount backplates first and snap in devices after painting and finishing. Digital Voltage Meter diagnostic test points on the horn strobe let technicians verify voltage at the device without removing it from the mounting plate. The tamper-resistant housing in red with a clear lens delivers 88+ dBA at 16V and mounts to standard electrical boxes in commercial, institutional, and educational facilities.\u003c\/p\u003e\n\u003ch3\u003eWhere the P2RLED Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffice buildings, corporate facilities, and mixed-use commercial spaces\u003c\/strong\u003e where the LED technology reduces current draw on the notification appliance circuit, allowing more devices per NAC power supply and reducing panel and power supply counts on large projects, while the selectable candela output configures each device for hallways, open offices, and conference rooms without changing the part number\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, universities, and institutional buildings\u003c\/strong\u003e where backward compatibility with SpectrAlert and SpectrAlert Advance systems allows phased upgrades from legacy notification devices to L-Series without replacing the fire alarm panel or NAC wiring, and the plug-in mounting design speeds installation across buildings with hundreds of notification points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospitals, assisted living facilities, and healthcare environments\u003c\/strong\u003e where the rotary horn tone and volume switches allow each device to be configured for the noise level of its specific area, the DVM test points simplify annual inspection without disrupting occupied spaces, and the shorting spring maintains NAC circuit supervision during device maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the P2RLED Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Strobe with Selectable Candela:\u003c\/strong\u003e LED technology provides lower current draw than xenon across the full candela range. Field-selectable candela output via rotary switch configures each device for its specific installation location. Clear lens on red housing for code-compliant visual notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e88+ dBA Horn with Tone and Volume Control:\u003c\/strong\u003e Audible output of 88+ dBA at 16V with rotary switches for field-selectable horn tones and high\/low volume settings. 2-wire operation on 24VDC notification appliance circuits. Tamper-resistant wall-mount housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectrAlert and L-Series Compatibility:\u003c\/strong\u003e Electrically compatible with SpectrAlert, SpectrAlert Advance, and all L-Series notification devices for seamless integration into existing and new fire alarm systems. Maintains synchronization across mixed-generation NAC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-In Installation with DVM Diagnostics:\u003c\/strong\u003e Universal mounting plate with built-in shorting spring maintains NAC circuit continuity during device installation and removal. Digital Voltage Meter test points allow in-place voltage verification. Mounts to standard electrical boxes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":51308490653880,"sku":"P2RLED","price":81.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-02at5.18.44PM.png?v=1748909930"},{"product_id":"system-sensor-cs-24w-ceiling-horn-strobe-white","title":"System Sensor CS-24W White Ceiling-Mount Horn\/Strobe","description":"\u003cp\u003e\u003cstrong\u003eSystem Sensor CS-24W White Ceiling-Mount Horn\/Strobe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe System Sensor CS-24W is a ceiling-mount horn\/strobe that delivers reliable audible and visual emergency signaling with tamperproof field-selectable settings. Designed for versatile use in fire protection systems, this white unit offers selectable candela outputs of 15, 30, 75, 95, 115, and 150 to meet varying installation requirements. With low current consumption and easy-to-change tone and volume switches, this device simplifies installation while enhancing performance.\u003c\/p\u003e\n\u003cp\u003eEngineered for flexibility, the CS-24W includes a Super-Slide® mounting bracket for faster wiring, Checkmate® instant voltage verification, and synchronization capabilities via the Gentex AVSM Control Module. The unit allows for temporal 3 or continuous tones, and supports both mechanical and 2400Hz sound options, all adjustable via field switches. Compatible with the CLNGBB ceiling surface-mount back box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Low current consumption with nominal 24VDC operation\u003cbr\u003e- Field-selectable candela settings: 15, 30, 75, 95, 115, 150\u003cbr\u003e- Switch options for mechanical or 2400Hz tone\u003cbr\u003e- Continuous or temporal 3 pattern settings\u003cbr\u003e- High or low dBA output options\u003cbr\u003e- Super-Slide® bracket simplifies supervision testing\u003cbr\u003e- Checkmate® instant voltage verification\u003cbr\u003e- Surface mount using CLNGBB (sold separately)\u003cbr\u003e- White finish with tamperproof re-entrant grill\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eIndoor ceiling-mounted fire protection installations that require dependable horn\/strobe signaling and simplified field customization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThe CS-24W combines high performance, flexible configuration, and low maintenance to support efficient emergency communication while reducing installation time and cost.\u003c\/p\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":51308498944184,"sku":"CS-24W","price":66.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-02at5.36.46PM.png?v=1748911012"},{"product_id":"pad300-pd-photoelectric-smoke-detector","title":"Potter PAD300-PD Analog Addressable Photoelectric Smoke Detector","description":"\u003cp\u003e\u003cstrong\u003ePotter PAD300-PD Analog Addressable Photoelectric Smoke Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PAD300-PD from Potter is a UL-listed, low-profile analog addressable photoelectric smoke detector designed for reliable fire detection using the PAD protocol. With a sensitivity range of 1.1 to 3.5% per foot, this detector ensures accurate performance in a wide range of applications. Built with durable off-white plastic to blend with most ceiling finishes, the PAD300-PD is compatible with any PAD300 series base and easily installs via twist-lock mounting.\u003c\/p\u003e\n\u003cp\u003eThe detector supports advanced features such as drift compensation, dirty detector warning, DIP switch address configuration, and a magnetic test switch. It also includes a built-in LED alarm indicator and communicates sensitivity directly to the control panel for real-time diagnostics and monitoring. The robust digital communication between the detector and control panel allows for total polling speed under five seconds, ensuring fast and accurate system responses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e- Low profile design, less than 2 inches with base\u003cbr\u003e- Wide sensitivity range: 1.1 to 3.5% per foot\u003cbr\u003e- UL listed smoke calibration and sensitivity\u003cbr\u003e- Drift compensation and dirty detector alert\u003cbr\u003e- LED alarm indicator for visual notification\u003cbr\u003e- Simple DIP switch addressing – no special tools needed\u003cbr\u003e- Compatible with PAD300 series bases\u003cbr\u003e- Optional locking tab for tamper resistance\u003cbr\u003e- UUKL Listed for Smoke Control\u003cbr\u003e- UL268 7th Edition Compliant\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eFacilities requiring addressable smoke detection with real-time communication, quick installation, and reliable performance under UL and UUKL standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThe PAD300-PD offers dependable fire detection with modern features like drift compensation and magnetic testing while minimizing installation time through simple DIP switch addressing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Highlights:\u003c\/strong\u003e\u003cbr\u003e- Compatible with all PAD300 series bases\u003cbr\u003e- Less than 5-second polling speed\u003cbr\u003e- Simple twist-lock installation\u003cbr\u003e- DIP switch address setup—no programming tool needed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PAD300-PD compatible with older Potter control panels?\u003c\/strong\u003e\u003cbr\u003eA: The PAD300-PD is compatible only with fire alarm control panels that use the PAD protocol. Be sure to confirm compatibility with your specific panel model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the address set on the detector?\u003c\/strong\u003e\u003cbr\u003eA: The address is easily set using the built-in DIP switches located on the rear of the detector—no special programming tool is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the detector come with a base?\u003c\/strong\u003e\u003cbr\u003eA: The base is not included and must be purchased separately. The PAD300-PD is compatible with any PAD300 series base.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51320638734520,"sku":"PAD300-PD","price":73.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at5.05.35AM.png?v=1748952341"},{"product_id":"potter-pad100-sim-addressable-fire-alarm-monitor-module","title":"Potter PAD100-SIM Addressable Fire Alarm Monitor Module - Single Class B Input, Single SLC Address, IPA Compatible","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAddressable Single Input Monitor Module That Monitors One Class B Circuit on a Single SLC Loop Address with PAD Protocol Communication\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAD100-SIM is an addressable single input \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm monitor module\u003c\/a\u003e that monitors one Class B initiating device circuit while consuming only a single SLC loop address. This makes it the right choice for locations where a single contact-type device such as a waterflow switch, tamper switch, or pull station needs to be brought onto the addressable loop without wasting a dual-input module on a single point. The PAD100-SIM uses the PAD protocol for addressable communication on the SLC loop, with a standby current of just 240 microamps to keep total loop power draw low across large systems.\u003c\/p\u003e\n\u003cp\u003eThe PAD100-SIM is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e PAD Series and shares the same compact 4.17 x 4.17 x 1.14-inch housing as the dual-input PAD100-DIM, mounting directly to a standard 4-inch square or double gang electrical box. A red LED flashes during normal panel polling and blinks rapidly when the input activates, providing instant visual identification during walk testing and alarm events. Each IDC supports up to 100 ohms of wiring resistance and 1 microfarad of capacitance, with a 5.1K ohm end-of-line resistor supervising the circuit. Up to 127 PAD100-SIM modules can be installed on a single SLC loop.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAD100-SIM Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone waterflow or tamper switch monitoring points\u003c\/strong\u003e where only one initiating device needs to connect to the addressable loop at a given location, the single-input design conserves SLC addresses compared to using a dual-input module for a single device, and the 240 microamp standby current minimizes loop power consumption across systems with hundreds of addressable devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull station connections and door holder relay monitoring\u003c\/strong\u003e where a single Class B circuit ties one contact-type device into the Potter IPA Series panel, the compact housing fits inside existing electrical boxes without adding junction boxes, and the red LED provides instant visual confirmation during walk testing and alarm events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouse and industrial sprinkler zones with single-device risers\u003c\/strong\u003e where each riser has only a waterflow switch without a paired tamper, the PAD protocol communication maintains reliable polling across long wire runs, and the 32 to 120 degree Fahrenheit operating range handles mechanical room and riser closet environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAD100-SIM Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Input on a Single Address:\u003c\/strong\u003e Monitors one Class B initiating device circuit while using only one SLC loop address. Connects waterflow switches, tamper switches, pull stations, and other contact-type devices to the addressable loop without consuming a dual-input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Current Addressable Communication:\u003c\/strong\u003e 240 microamp standby and alarm current on the SLC loop minimizes power draw across large systems. PAD protocol communication with red LED status indicator that flashes during polling and blinks rapidly on input activation. Up to 127 modules per SLC loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised IDC Circuit:\u003c\/strong\u003e The initiating device circuit supports up to 100 ohms of wiring resistance and 1 microfarad of capacitance. 5.1K ohm end-of-line resistor provides continuous circuit supervision. Operating temperature range of 32 to 120 degrees Fahrenheit with humidity tolerance to 93% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Mounting:\u003c\/strong\u003e 4.17 x 4.17 x 1.14-inch housing mounts to a standard 4-inch square or double gang electrical box. 24V DC operating voltage from the SLC loop. Compatible with Potter IPA Series fire alarm panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat Does a Fire Alarm Monitor Module Do\u003c\/h3\u003e\n\u003cp\u003eA fire alarm monitor module connects a conventional contact-type device to an addressable fire alarm panel by monitoring the state of an initiating device circuit and reporting changes back to the panel over the SLC loop. When a connected device such as a waterflow switch, tamper switch, or pull station activates, the monitor module detects the change in circuit state and transmits its unique address to the panel, which identifies the exact device location and initiates the programmed response. The PAD100-SIM handles this for a single Class B circuit on one SLC address, making it the efficient choice when only one device needs monitoring at a given location.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51320949080248,"sku":"PAD100-SIM","price":74.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at5.11.37AM.png?v=1748952703"},{"product_id":"pad100-mim-micro-input-module","title":"PAD100-MIM Micro Input Module","description":"\u003cp\u003e\u003cstrong\u003ePAD100-MIM Micro Input Module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PAD100-MIM is a compact, addressable input module designed to monitor the status of initiating devices that use a normally open set of dry contacts. Housed in a protective plastic enclosure to guard against accidental shorts and ground faults, this module offers both reliable monitoring and convenient installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e• Monitors dry contact initiating devices\u003cbr\u003e• Protective plastic case prevents shorts and ground faults\u003cbr\u003e• Single-screw mounting for simple installation\u003cbr\u003e• Status LED for communication and alarm indication\u003cbr\u003e• LED flashes during polling, rapid flash during activation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eApplications requiring addressable monitoring of pull stations or similar devices, particularly in enclosures or electrical boxes behind the initiating device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThe PAD100-MIM provides a compact and efficient solution for integrating dry-contact initiating devices into addressable fire alarm systems, with real-time LED status feedback and straightforward mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Highlights:\u003c\/strong\u003e\u003cbr\u003e• Compatible with Potter IPA and AFC\/ARC addressable panels\u003cbr\u003e• Supports normally open dry contact devices\u003cbr\u003e• Designed for in-box or enclosure installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What type of initiating devices can the PAD100-MIM monitor?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It monitors devices with a normally open dry contact set.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What control panels is this compatible with?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It works with Potter IPA and AFC\/ARC series panels.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What does the LED indicate?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A slow flash indicates polling; a fast flash signals input activation.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51321389187256,"sku":"PAD100-MIM","price":65.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at5.28.09AM.png?v=1748953697"},{"product_id":"system-sensor-co1224t-carbon-monoxide-detector","title":"System Sensor CO1224T Carbon Monoxide Detector","description":"\u003cp\u003e\u003cstrong\u003eSystem Sensor CO1224T Carbon Monoxide Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe System Sensor CO1224T is a carbon monoxide detector equipped with RealTest® technology, allowing for functional testing using canned CO gas. Featuring a highly accurate electrochemical sensing cell, the CO1224T provides early warning of dangerous carbon monoxide levels while offering full compliance with code-required safety features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e• RealTest® allows functional testing with CO gas\u003cbr\u003e• Code-required trouble relay for sensor failure or end-of-life\u003cbr\u003e• SEMS terminals with Philips-head screws for wiring supervision\u003cbr\u003e• Compatible with 12\/24 VDC systems\u003cbr\u003e• Low current draw for efficient system integration\u003cbr\u003e• Mounts easily to wall or ceiling\u003cbr\u003e• Reliable electrochemical CO sensing\u003cbr\u003e• Integrated 10-year end-of-life timer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eSecurity and fire alarm systems requiring code-compliant carbon monoxide detection, particularly in residential or light commercial environments with 24\/7 central station monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThe CO1224T delivers dependable life safety protection with minimal current draw, intuitive wiring, and the added assurance of RealTest® functionality to verify sensor performance on-site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Highlights:\u003c\/strong\u003e\u003cbr\u003e• Functional CO testing using RealTest® mode\u003cbr\u003e• Low-profile design with flexible installation\u003cbr\u003e• Works with most industry-standard fire\/security control panels\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e How do I test the detector?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Enter RealTest® mode and apply a CO test agent. The alarm will sound within seconds.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What is the detector's lifespan?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It includes a built-in 10-year end-of-life timer.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e Is it compatible with fire and security panels?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it works with most 12\/24VDC control panels on the market.\u003c\/p\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":51322905788600,"sku":"CO1224T","price":95.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at6.07.52AM.png?v=1748956077"},{"product_id":"potter-hs-24wr-horn-strobe-selectable-candela","title":"Potter HS-24WR Horn Strobe - Selectable 15-110 Candela, 6 Tones, 24VDC Wall Mount, Red, UL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSelectable Candela Horn Strobe with Six Field-Switchable Tones, Super-Slide Mounting, and Checkmate Voltage Verification for 24VDC Notification Appliance Circuits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter HS-24WR is a selectable candela \u003ca href=\"\/collections\/fire-alarm-systems\"\u003ehorn strobe\u003c\/a\u003e that delivers audible and visual fire alarm notification with field-adjustable 15, 30, 60, 75, and 110 candela settings and six switchable tones in a low-profile red wall-mount housing. The selectable candela output lets installers configure each device for its specific location without stocking multiple part numbers, and the six tone options including temporal three, continuous, 2400Hz, mechanical, chime, and whoop cover the full range of code requirements and facility preferences. The HS-24WR operates on 24VDC from the fire alarm panel notification appliance circuit with minimal current draw and a consistent 1Hz flash rate.\u003c\/p\u003e\n\u003cp\u003eThe HS-24WR is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e HS-24 Series and ships with a standard 4-inch metal mounting plate featuring the Super-Slide bracket for fast installation and easy supervision testing access. The Checkmate Instant Voltage Verification feature lets technicians confirm proper wiring and voltage drop at the device without a multimeter, speeding commissioning and annual inspections across large notification appliance circuits. The tamperproof locking mechanism conceals mounting screws to prevent unauthorized removal, and the unit carries ANSI\/UL 464 and ANSI\/UL 1971 listings for fire protective signaling applications.\u003c\/p\u003e\n\u003ch3\u003eWhere the HS-24WR Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial office buildings and corporate campuses\u003c\/strong\u003e where the selectable 15 to 110 candela output configures each device for hallways, open offices, conference rooms, and lobbies without changing the part number, the six field-switchable tones allow different zones to use different alarm signals, and the minimal current draw supports more devices per notification appliance circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, universities, and institutional buildings\u003c\/strong\u003e where the Super-Slide mounting plate speeds annual NFPA testing by providing easy access for supervision verification, the Checkmate voltage verification eliminates the need for a multimeter at each device during commissioning, and the tamperproof locking mechanism prevents unauthorized removal in high-traffic corridors and stairwells\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealthcare facilities and assisted living environments\u003c\/strong\u003e where the six tone options allow each floor or wing to use a distinct alarm pattern for staff recognition, the low-profile housing fits into finished ceilings and walls without drawing attention, and the selectable candela range accommodates both small patient rooms and large common areas on the same notification appliance circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the HS-24WR Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Candela Output:\u003c\/strong\u003e Field-adjustable 15, 30, 60, 75, and 110 candela settings via selector switch. Consistent 1Hz flash rate across all candela levels. 24VDC operation with minimal current draw from the fire alarm panel notification appliance circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Field-Switchable Tones:\u003c\/strong\u003e Temporal three (synchronized), continuous, 2400Hz, mechanical, chime, and whoop tone patterns selectable in the field. Covers the full range of NFPA 72 and local code requirements for audible fire alarm notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuper-Slide Mounting with Checkmate Verification:\u003c\/strong\u003e Standard 4-inch metal mounting plate with Super-Slide bracket for fast installation and supervision testing access. Checkmate Instant Voltage Verification confirms wiring and voltage drop at the device without a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTamperproof UL Listed Housing:\u003c\/strong\u003e Red low-profile wall-mount housing with tamperproof locking mechanism that conceals mounting screws. ANSI\/UL 464 and ANSI\/UL 1971 listed for fire protective signaling applications. 3-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51323474346168,"sku":"HS-24WR","price":65.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at6.27.31AM.png?v=1748957258"},{"product_id":"potter-pam-1-relay-module-multi-voltage","title":"Potter PAM-1 Multi-Voltage Relay Module - 10A SPDT, 24VAC\/24VDC\/120VAC, Encapsulated, UL Recognized","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eMulti-Voltage Encapsulated Relay Module with 10A Form C Contacts, LED Status Indicator, and 24VAC\/24VDC\/120VAC Input Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAM-1 is a multi-voltage encapsulated relay module that provides 10-amp Form C (SPDT) contact switching for \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm\u003c\/a\u003e, HVAC, security, lighting, and energy management systems. The relay accepts 24VAC, 24VDC, or 120VAC input, allowing a single part number to work across the full range of control voltages found in commercial buildings without stocking separate modules for each voltage. An integrated red LED indicates when the relay coil is energized, giving installers and maintenance technicians instant visual confirmation of relay state without a meter.\u003c\/p\u003e\n\u003cp\u003eThe PAM-1 is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e PAM Series of encapsulated relay modules and measures just 1.50 x 1.20 x 0.77 inches, making it compact enough to fit inside junction boxes, behind control panels, or anywhere space is limited. Three mounting options including adhesive tape, self-drilling screw, and loose placement in a backbox provide flexibility for any installation condition. The module draws 20mA at 24VDC and 50mA at 24VAC or 120VAC, with 12-inch 18-gauge wire leads for direct connection to the control circuit. The relay is UL recognized and operates across an ambient temperature range of 32 to 120 degrees Fahrenheit.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAM-1 Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire alarm panel auxiliary relay applications\u003c\/strong\u003e where the panel trigger voltage activates the PAM-1 to switch HVAC dampers, elevator recall circuits, door holders, or other building systems, the multi-voltage input accepts whatever control voltage the panel provides, and the encapsulated design protects the relay from dust and debris in mechanical rooms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC and building automation systems\u003c\/strong\u003e where control sequences require relay switching between 24VAC and 120VAC circuits, the compact 1.50 x 1.20 x 0.77-inch form factor fits inside existing control enclosures without additional space, and the 10-amp contact rating handles fan relays, damper actuators, and motor loads without an intermediate contactor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity and access control integrations\u003c\/strong\u003e where door holder releases, magnetic lock power supplies, or alarm output circuits need a general-purpose switching module, the red LED confirms relay state during commissioning and troubleshooting, and the adhesive mounting option allows quick placement in tight spaces behind panels and inside backboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAM-1 Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10A Form C Contacts with Multi-Voltage Input:\u003c\/strong\u003e SPDT contact rated 10A at 120VAC and 7A at 24VDC. Accepts 24VAC, 24VDC, or 120VAC input for single-part-number compatibility across commercial control voltage standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRed LED Status Indicator:\u003c\/strong\u003e Integrated red LED illuminates when the relay coil is energized for visual confirmation of relay state without a meter. Draws 20mA at 24VDC and 50mA at 24VAC or 120VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Encapsulated Design:\u003c\/strong\u003e 1.50 x 1.20 x 0.77-inch encapsulated housing with 12-inch 18-gauge wire leads for direct wiring. UL recognized SPDT relay rated for 32 to 120 degrees Fahrenheit ambient temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting Options:\u003c\/strong\u003e Adhesive tape, self-drilling screw, or loose placement in backbox accommodates any installation condition. Fits standard junction boxes and control enclosures in fire alarm, HVAC, security, and energy management applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51323830337720,"sku":"PAM-1","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at6.36.39AM.png?v=1748957805"},{"product_id":"potter-pad100-rm-addressable-fire-alarm-relay-module","title":"Potter PAD100-RM Addressable Fire Alarm Relay Module - Form C Contact, Single SLC Address, IPA Compatible","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAddressable Relay Module with One Form C Output Contact on a Single SLC Loop Address for Fire Alarm Control Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAD100-RM is an addressable \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm relay module\u003c\/a\u003e that provides one Form C relay contact output while consuming only a single SLC loop address. The relay output allows the fire alarm panel to control external devices such as door holders, HVAC fan shutdowns, elevator recall circuits, and damper actuators through programmed automation sequences. The PAD100-RM uses the PAD protocol for addressable communication on the SLC loop, with a standby current of just 240 microamps to keep total loop power draw low across large systems.\u003c\/p\u003e\n\u003cp\u003eThe PAD100-RM is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e PAD100 Series of addressable modules and shares the same compact 4.17 x 4.17 x 1.14-inch housing as the monitor modules in the family, mounting directly to a standard 4-inch square or double gang electrical box. The Form C relay contact is rated at 2 amps at 30VDC and 0.5 amps at 125VAC, handling the load requirements of common fire alarm control applications. A red LED flashes during normal panel polling to confirm communication status, and up to 127 PAD100-RM modules can be installed on a single SLC loop. The module operates on 24V DC from the SLC loop and is compatible with Potter IPA Series fire alarm panels.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAD100-RM Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial buildings with HVAC shutdown and door holder release requirements\u003c\/strong\u003e where the fire alarm panel needs to switch external circuits at specific locations, the addressable relay output ties directly into programmed automation sequences, and the single SLC address conserves loop capacity across buildings with dozens of control points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-rise towers and healthcare facilities with elevator recall and damper control\u003c\/strong\u003e where code-required automation depends on relay outputs at specific floor and zone locations, the 2-amp contact rating at 30VDC handles elevator recall relays and damper actuators, and the compact housing fits inside standard electrical boxes alongside other fire alarm modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial and warehouse facilities with zone-specific equipment shutdowns\u003c\/strong\u003e where the fire alarm panel controls exhaust fans, process equipment interlocks, or access control releases through relay modules at each zone, the PAD protocol communication maintains reliable control across long SLC wire runs, and the 32 to 120 degree Fahrenheit operating range handles mechanical room environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAD100-RM Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm C Relay Contact Output:\u003c\/strong\u003e One Form C (SPDT) relay contact rated 2A at 30VDC and 0.5A at 125VAC. Controls door holders, HVAC shutdowns, elevator recall, damper actuators, and other fire alarm automation outputs using a single SLC loop address.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Current Addressable Communication:\u003c\/strong\u003e 240 microamp standby and alarm current on the SLC loop minimizes power draw across large systems. PAD protocol communication with red LED status indicator that flashes during panel polling. Up to 127 modules per SLC loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Mounting:\u003c\/strong\u003e 4.17 x 4.17 x 1.14-inch housing mounts to a standard 4-inch square or double gang electrical box. 24V DC operating voltage from the SLC loop. Operating temperature range of 32 to 120 degrees Fahrenheit with humidity tolerance to 93% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPA Panel Compatible:\u003c\/strong\u003e Integrates with Potter IPA Series fire alarm panels for addressable relay control across the SLC loop. Same PAD100 form factor as the SIM and DIM monitor modules for consistent installation across the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat Is a Fire Alarm Relay Module\u003c\/h3\u003e\n\u003cp\u003eA fire alarm relay module is an addressable output device that allows the fire alarm control panel to switch external circuits and equipment in response to alarm conditions or programmed automation sequences. When the panel activates the relay module, its Form C contact changes state to energize or de-energize a connected load such as a door holder, HVAC fan, elevator recall circuit, or smoke damper actuator. The PAD100-RM provides this relay output on a single SLC loop address with a contact rating of 2 amps at 30VDC, making it the right choice for control applications where the panel needs to directly switch low-voltage equipment at specific points throughout the building.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51324028354744,"sku":"PAD100-RM","price":91.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at6.42.38AM.png?v=1748958165"},{"product_id":"smoke-detector-tester-2-5-oz-aerosol","title":"Smoke Detector Tester – 2.5 oz Aerosol","description":"\u003cp\u003e\u003cstrong\u003eSmoke Detector Tester – 2.5 oz Aerosol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis 2.5 oz aerosol smoke detector tester is a reliable solution for verifying the functionality of both photoelectric and ionization smoke detectors in residential or commercial environments. Designed in accordance with NFPA 72 Chapter 14, this tester simulates the full range of fire conditions to ensure your detectors are accurately sampling the air and ready to respond.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e• 2.5 oz aerosol can for easy application\u003cbr\u003e• Tests both photoelectric and ionization detectors\u003cbr\u003e• Verifies alarm circuitry, power, and sampling accuracy\u003cbr\u003e• Fully compliant with EPA standards\u003cbr\u003e• Environmentally friendly formula\u003cbr\u003e• Meets NFPA, OSHA, and UL standards\u003cbr\u003e• Ideal for residential and commercial smoke detectors\u003cbr\u003e• Interconnection capability: None required\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eElectricians, building inspectors, and facility managers who need a compliant and effective tool for smoke detector maintenance and testing in any environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy You Should Use This:\u003c\/strong\u003e\u003cbr\u003eThis EPA-compliant tester ensures peace of mind by simulating realistic fire conditions, giving you confidence that your smoke detectors will respond when needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Highlights:\u003c\/strong\u003e\u003cbr\u003e• NFPA 72 Chapter 14 approved usage\u003cbr\u003e• Tests full fire condition response range\u003cbr\u003e• No special interconnect systems required\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What types of detectors does this tester work with?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It’s designed for both photoelectric and ionization smoke detectors.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e What environments is it suitable for?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It’s ideal for residential and commercial use.\u003c\/p\u003e","brand":"Island Electrical Supply","offers":[{"title":"Default Title","offer_id":51324428320952,"sku":"25S","price":18.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at6.53.26AM.png?v=1748958814"},{"product_id":"silent-knight-5860-remote-annunciator-lcd","title":"Silent Knight 5860R Remote LCD Annunciator - 80 Character Display, IntelliKnight Compatible, RS-485, Red","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e80-Character LCD Remote Annunciator with Full Panel Control, RS-485 Communication, and Multi-Location Support for IntelliKnight Fire Alarm Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Silent Knight 5860R is an 80-character LCD remote \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm annunciator\u003c\/a\u003e that extends full control of IntelliKnight fire alarm panels to up to twelve locations throughout a building. The backlit LCD display provides clear, real-time system status information, and the ergonomic keypad with tactile and audible feedback allows authorized personnel to perform all panel operations including system reset, alarm silence, fire drill activation, and full programming from any annunciator location. The 5860R communicates with the fire alarm panel over an RS-485 system bus with wire runs up to 6,000 feet.\u003c\/p\u003e\n\u003cp\u003eThe 5860R is manufactured by Honeywell under the Silent Knight brand and is compatible with IntelliKnight panels including the 5820XL, 5820XL-EVS, 5808, and 5700 addressable fire alarm control panels. Access is secured through a firefighter's key or user code for standard operations, and programming functions require a separate installer code to prevent unauthorized changes. The red housing measures 9.1 x 7.4 x 1.5 inches and operates on 24V DC power from the fire alarm system bus. The interface is identical to the panel's built-in annunciator, so building staff and first responders operate it with the same familiarity as the main panel.\u003c\/p\u003e\n\u003ch3\u003eWhere the 5860R Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-story commercial buildings and corporate campuses\u003c\/strong\u003e where fire code requires remote annunciation at the main entrance, security desk, and mechanical room locations, up to twelve annunciators can be distributed throughout the building on a single RS-485 bus, and wire runs up to 6,000 feet cover even the largest floor plates and campus layouts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, hospitals, and institutional facilities\u003c\/strong\u003e where first responders need immediate system access from lobby-mounted annunciators without walking to the main panel location, the firefighter's key provides secure panel control for emergency operations, and the 80-character LCD displays specific device and zone information for faster incident identification and response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-tenant buildings and campus environments\u003c\/strong\u003e where building management needs local system control at each building while the main IntelliKnight panel sits in a central location, full programming capability via installer code allows on-site configuration changes during system expansion, and compatibility with four IntelliKnight panel models covers installations from small to large\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the 5860R Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80-Character Backlit LCD Display:\u003c\/strong\u003e Real-time system status with full text messaging for alarm, trouble, and supervisory conditions. Ergonomic keypad with tactile and audible feedback for all panel operations including reset, silence, fire drill, and programming.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Panel Control from Remote Locations:\u003c\/strong\u003e Up to twelve annunciators per system provide complete panel control from distributed locations. Secured via firefighter's key or user code for standard operations. Separate installer code required for programming access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 System Bus Communication:\u003c\/strong\u003e Wire runs up to 6,000 feet between annunciator and panel. 24V DC operation from the fire alarm system bus. Same interface as the panel's built-in annunciator for familiar operation by building staff and first responders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliKnight Panel Compatibility:\u003c\/strong\u003e Works with Silent Knight 5820XL, 5820XL-EVS, 5808, and 5700 addressable fire alarm control panels. Red housing, 9.1 x 7.4 x 1.5 inches. UL Listed. Made in USA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":51324787392696,"sku":"SK-5860R","price":612.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at7.00.49AM.png?v=1748959255"},{"product_id":"potter-ra-6500-fire-alarm-annunciator-lcd","title":"Potter RA-6500 Fire Alarm Annunciator - 160 Character LCD, RS-485, PFC-6000 Compatible, Red","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e160-Character LCD Remote Annunciator with Full System Control, RS-485 Communication, and Support for Up to 31 Annunciators on PFC-6000 Fire Alarm Panels\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter RA-6500 is a 160-character LCD remote \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm annunciator\u003c\/a\u003e that provides full system monitoring and control for PFC-6000 Series addressable fire alarm panels from up to 31 remote locations throughout a building. The 4x40 LCD display delivers detailed text messaging for alarm, supervisory, trouble, and system status conditions, while dedicated LED indicators for power, alarm, supervisory, trouble, and silenced states give operators instant visual confirmation of system condition at a glance. The RA-6500 communicates with the main panel over RS-485 with wire runs up to 6,500 feet.\u003c\/p\u003e\n\u003cp\u003eThe RA-6500 is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e PFC-6000 Series ecosystem and features a Potter locking mechanism that secures keypad access to authorized personnel. The durable sheet metal enclosure mounts to a single gang or 4-inch square electrical box, drawing just 20mA in standby and 25mA in alarm for minimal impact on the panel power supply. The unit accepts 14 to 22 AWG wire and operates across a temperature range of 32 to 120 degrees Fahrenheit with humidity tolerance to 93% non-condensing.\u003c\/p\u003e\n\u003ch3\u003eWhere the RA-6500 Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-story commercial buildings and corporate campuses\u003c\/strong\u003e where up to 31 annunciators can be distributed across lobbies, security desks, mechanical rooms, and fire command centers, the 6,500-foot wire run covers the largest floor plates and campus layouts, and the 160-character LCD provides enough detail to identify specific devices and zones during an alarm event\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospitals, universities, and institutional campuses\u003c\/strong\u003e where dedicated LED indicators for power, alarm, supervisory, trouble, and silenced states give first responders immediate condition identification from across the room, the Potter locking mechanism restricts keypad access to authorized personnel, and full panel control capability eliminates the need to walk to the main panel location during emergency operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial complexes and warehouse facilities\u003c\/strong\u003e where the sheet metal enclosure handles the rigors of mechanical rooms and maintenance areas, 14 to 22 AWG wiring flexibility accommodates existing cable infrastructure, and the 20mA standby current allows multiple annunciators on the RS-485 bus without overloading the panel power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the RA-6500 Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160-Character LCD with LED Indicators:\u003c\/strong\u003e 4x40 backlit LCD display provides detailed text messaging for alarm, supervisory, trouble, and system status conditions. Dedicated LED indicators for power, alarm, supervisory, trouble, and silenced states for instant visual status identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Remote System Control:\u003c\/strong\u003e All panel operations accessible from up to 31 remote annunciator locations on a single RS-485 bus. Potter locking mechanism secures keypad access to authorized personnel only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Communication:\u003c\/strong\u003e Wire runs up to 6,500 feet between annunciator and PFC-6000 panel. Accepts 14 to 22 AWG wire. 20mA standby current and 25mA alarm current for minimal power supply impact across multiple annunciators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePFC-6000 Compatible Mounting:\u003c\/strong\u003e Durable sheet metal enclosure mounts to single gang or 4-inch square electrical box. 10 x 7-7\/8 x 1-5\/8 inches. Operating range 32 to 120 degrees Fahrenheit, 10 to 93% humidity non-condensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat Is a Fire Alarm Annunciator\u003c\/h3\u003e\n\u003cp\u003eA fire alarm annunciator is a remote display and control unit that connects to a fire alarm control panel to provide system status information and operator access from a location other than the main panel. Building codes often require annunciators at building entrances, fire command centers, and security desks so that first responders and building staff can immediately see the system condition and take action without walking to the main fire alarm panel. The RA-6500 serves this role for Potter PFC-6000 Series panels, providing a 160-character LCD display with full system control and support for up to 31 annunciator locations on a single RS-485 bus with wire runs up to 6,500 feet.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51326154539192,"sku":"RA-6500FR","price":588.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at7.43.08AM.png?v=1748961798"},{"product_id":"potter-pfc-6006-conventional-fire-alarm-panel","title":"Potter PFC-6006 Conventional Fire Alarm Control Panel - 6 Zone, Dual-Line DACT, 120VAC, UL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e6-Zone Conventional Fire Alarm Control Panel with Dual-Line DACT, Class A\/B Waterflow Input, and Built-In 1.0A Power Supply for Small to Mid-Size Fire Protection Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PFC-6006 is a 6-zone conventional \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm control panel\u003c\/a\u003e designed for small to mid-size fire protection systems including sprinkler monitoring, zone detection, and central station reporting. Six programmable input zones include one selectable Class A\/B waterflow input and support for two-wire smoke detectors, while the onboard dual-line DACT connects to monitoring stations for remote alarm reporting and system programming. The built-in 1.0-amp power supply delivers 0.5A to the notification appliance circuit and 0.5A of auxiliary power that can be set to constant or resettable output.\u003c\/p\u003e\n\u003cp\u003eThe PFC-6006 is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e conventional fire panel lineup and operates on 120VAC 60Hz in a lockable 18-gauge sheet steel cabinet with a Lexan viewing window. The 32-character LCD display provides clear system status readout, an event history buffer logs alarm and trouble events, and the removable circuit assembly simplifies installation and service. P-Link bus communication supports up to four RA-6075 remote annunciators for multi-location monitoring in larger buildings.\u003c\/p\u003e\n\u003ch3\u003eWhere the PFC-6006 Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall commercial buildings and retail spaces\u003c\/strong\u003e where six programmable zones cover the sprinkler system and basic detection needs, the Class A\/B waterflow input monitors the fire sprinkler riser, and the dual-line DACT reports alarms to a central monitoring station without adding a separate communicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial facilities and warehouses with sprinkler monitoring\u003c\/strong\u003e where the conventional zone architecture provides straightforward coverage without the complexity and cost of an addressable system, the 0.5A NAC output powers horn strobes across the notification circuit, and the lockable steel cabinet withstands mechanical room environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall institutional and educational buildings\u003c\/strong\u003e where up to four RA-6075 remote annunciators on the P-Link bus extend system status to multiple locations throughout the building, the 32-character LCD gives operators detailed alarm and trouble information, and UL-864 listing meets authority having jurisdiction requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PFC-6006 Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 Programmable Zones with Class A\/B Waterflow:\u003c\/strong\u003e Six input zones including one selectable Class A\/B waterflow input and support for two-wire smoke detectors. Programmable zone types accommodate sprinkler monitoring, manual pull stations, and detector circuits in a single panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Line DACT for Central Station Reporting:\u003c\/strong\u003e Onboard dual-line digital alarm communicator transmitter connects to monitoring stations for alarm, supervisory, and trouble reporting. Supports remote programming for off-site system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In 1.0A Power Supply:\u003c\/strong\u003e 1.0 amp at 120VAC 60Hz with 0.5A NAC output and 0.5A auxiliary power. Auxiliary output selectable between constant and resettable. Battery standby current of 105mA and alarm current of 160mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockable Steel Cabinet with LCD Display:\u003c\/strong\u003e 18-gauge sheet steel enclosure with hinged, removable locked door and Lexan viewing window. 32-character LCD display with system status LEDs and event history buffer. 18-1\/2 x 14-1\/4 x 4-3\/4 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Annunciator Support:\u003c\/strong\u003e P-Link bus supports up to four RA-6075 remote annunciators for multi-location system monitoring. Removable circuit assembly for simplified installation and service. UL-864, NFPA-70, and NFPA-72 listed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat Is a Conventional Fire Alarm Panel\u003c\/h3\u003e\n\u003cp\u003eA conventional fire alarm panel is a fire alarm control panel that monitors detection devices organized by zone rather than by individual device address. When a detector or pull station activates, the panel identifies the zone where the alarm originated but not the specific device, which keeps system cost and complexity lower than addressable panels for buildings with straightforward layouts. The PFC-6006 provides six programmable zones with Class A\/B waterflow monitoring and two-wire smoke detection support, making it a practical choice for small to mid-size commercial and institutional buildings where zone-level identification meets the fire protection requirements.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51326476157112,"sku":"PFC-6006-R","price":535.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at7.48.28AM.png?v=1748962114"}],"url":"https:\/\/islandelectricalsupply.com\/collections\/fire-alarm-systems.oembed","provider":"Island Electrical Supply","version":"1.0","type":"link"}