{"product_id":"potter-pad100-psda-addressable-fire-alarm-pull-station","title":"Potter PAD100-PSDA Addressable Fire Alarm Pull Station - Dual Action, Die-Cast Metal, UUKL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDual-Action Addressable Manual Pull Station with Die-Cast Metal Housing, DIP Switch Programming, and Class A\/B\/X SLC Wiring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PAD100-PSDA is a dual-action addressable \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm\u003c\/a\u003e pull station built with heavy-duty die-cast metal construction for commercial and institutional installations. The dual-action design requires the operator to lift the front cover before pulling the handle, which reduces false activations in high-traffic areas while maintaining immediate access during a real emergency. DIP switch addressing allows field programming without software tools, and the unit integrates directly with \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e IPA Series panels including the AFC-100, AFC-50, and ARC-100 through SLC wiring in Class A, Class B, or Class X configurations.\u003c\/p\u003e\n\u003cp\u003eOnce activated, the pull handle locks in place and cannot be reset without opening the front cover using the Potter WS-93 key, which matches the same key used on Potter fire alarm control panels for a single-key maintenance workflow. Opening the front cover alone also triggers an alarm, providing tamper protection against unauthorized access. The PAD100-PSDA is UUKL Listed for Smoke Control Systems and mounts in a standard single-gang box at 1.75 x 3.25 x 4.75 inches and 1.46 pounds.\u003c\/p\u003e\n\u003ch3\u003eWhere the PAD100-PSDA Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial office buildings and corporate campuses\u003c\/strong\u003e where the dual-action design prevents accidental activations from passersby and cleaning crews, the die-cast metal housing withstands daily contact in high-traffic hallways and stairwells, and addressable communication reports the exact pull station location to the fire alarm panel for faster emergency response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchools, hospitals, and institutional facilities\u003c\/strong\u003e where dual-action operation is required by code or preferred by the authority having jurisdiction to reduce nuisance alarms, the WS-93 key reset matches existing Potter panel keys so fire alarm technicians carry a single key for the entire system, and DIP switch programming simplifies addressing during initial installation and future device additions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarehouses, manufacturing plants, and loading docks\u003c\/strong\u003e where the die-cast metal construction handles industrial environments without cracking or warping, the tamper-triggered alarm on cover opening deters vandalism, and Class A\/B\/X SLC wiring flexibility accommodates the wiring topology required by the facility layout and code requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PAD100-PSDA Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Action Activation with Tamper Protection:\u003c\/strong\u003e Requires lifting the front cover before pulling the white T-bar handle to initiate an alarm. Once activated, the handle locks in the pulled position and requires a WS-93 key to reset. Opening the front cover alone triggers an alarm for tamper detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDie-Cast Metal Construction:\u003c\/strong\u003e Heavy-duty die-cast metal housing in red finish resists impact, tampering, and environmental wear in commercial and industrial installations. Dimensions: 1.75 x 3.25 x 4.75 inches. Weight: 1.46 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIP Switch Addressable with IPA Panel Compatibility:\u003c\/strong\u003e Field-programmable DIP switch addressing integrates with Potter IPA Series panels including AFC-100, AFC-50, and ARC-100. Supports SLC wiring in Class A, Class B, and Class X configurations for flexible installation topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUUKL Listed for Smoke Control:\u003c\/strong\u003e UL and UUKL Listed for Smoke Control Systems applications. Reset key matches Potter fire alarm control panel key (WS-93) for single-key maintenance across the entire fire alarm system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51199027118264,"sku":"PAD100-PSDA","price":132.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-05-28at10.48.38AM.png?v=1748454529","url":"https:\/\/islandelectricalsupply.com\/products\/potter-pad100-psda-addressable-fire-alarm-pull-station","provider":"Island Electrical Supply","version":"1.0","type":"link"}