{"product_id":"potter-pfc-6006-conventional-fire-alarm-panel","title":"Potter PFC-6006 Conventional Fire Alarm Control Panel - 6 Zone, Dual-Line DACT, 120VAC, UL Listed","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003e6-Zone Conventional Fire Alarm Control Panel with Dual-Line DACT, Class A\/B Waterflow Input, and Built-In 1.0A Power Supply for Small to Mid-Size Fire Protection Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Potter PFC-6006 is a 6-zone conventional \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire alarm control panel\u003c\/a\u003e designed for small to mid-size fire protection systems including sprinkler monitoring, zone detection, and central station reporting. Six programmable input zones include one selectable Class A\/B waterflow input and support for two-wire smoke detectors, while the onboard dual-line DACT connects to monitoring stations for remote alarm reporting and system programming. The built-in 1.0-amp power supply delivers 0.5A to the notification appliance circuit and 0.5A of auxiliary power that can be set to constant or resettable output.\u003c\/p\u003e\n\u003cp\u003eThe PFC-6006 is part of the \u003ca href=\"\/collections\/potter\"\u003ePotter\u003c\/a\u003e conventional fire panel lineup and operates on 120VAC 60Hz in a lockable 18-gauge sheet steel cabinet with a Lexan viewing window. The 32-character LCD display provides clear system status readout, an event history buffer logs alarm and trouble events, and the removable circuit assembly simplifies installation and service. P-Link bus communication supports up to four RA-6075 remote annunciators for multi-location monitoring in larger buildings.\u003c\/p\u003e\n\u003ch3\u003eWhere the PFC-6006 Fits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall commercial buildings and retail spaces\u003c\/strong\u003e where six programmable zones cover the sprinkler system and basic detection needs, the Class A\/B waterflow input monitors the fire sprinkler riser, and the dual-line DACT reports alarms to a central monitoring station without adding a separate communicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial facilities and warehouses with sprinkler monitoring\u003c\/strong\u003e where the conventional zone architecture provides straightforward coverage without the complexity and cost of an addressable system, the 0.5A NAC output powers horn strobes across the notification circuit, and the lockable steel cabinet withstands mechanical room environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall institutional and educational buildings\u003c\/strong\u003e where up to four RA-6075 remote annunciators on the P-Link bus extend system status to multiple locations throughout the building, the 32-character LCD gives operators detailed alarm and trouble information, and UL-864 listing meets authority having jurisdiction requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the PFC-6006 Delivers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 Programmable Zones with Class A\/B Waterflow:\u003c\/strong\u003e Six input zones including one selectable Class A\/B waterflow input and support for two-wire smoke detectors. Programmable zone types accommodate sprinkler monitoring, manual pull stations, and detector circuits in a single panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Line DACT for Central Station Reporting:\u003c\/strong\u003e Onboard dual-line digital alarm communicator transmitter connects to monitoring stations for alarm, supervisory, and trouble reporting. Supports remote programming for off-site system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In 1.0A Power Supply:\u003c\/strong\u003e 1.0 amp at 120VAC 60Hz with 0.5A NAC output and 0.5A auxiliary power. Auxiliary output selectable between constant and resettable. Battery standby current of 105mA and alarm current of 160mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockable Steel Cabinet with LCD Display:\u003c\/strong\u003e 18-gauge sheet steel enclosure with hinged, removable locked door and Lexan viewing window. 32-character LCD display with system status LEDs and event history buffer. 18-1\/2 x 14-1\/4 x 4-3\/4 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Annunciator Support:\u003c\/strong\u003e P-Link bus supports up to four RA-6075 remote annunciators for multi-location system monitoring. Removable circuit assembly for simplified installation and service. UL-864, NFPA-70, and NFPA-72 listed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat Is a Conventional Fire Alarm Panel\u003c\/h3\u003e\n\u003cp\u003eA conventional fire alarm panel is a fire alarm control panel that monitors detection devices organized by zone rather than by individual device address. When a detector or pull station activates, the panel identifies the zone where the alarm originated but not the specific device, which keeps system cost and complexity lower than addressable panels for buildings with straightforward layouts. The PFC-6006 provides six programmable zones with Class A\/B waterflow monitoring and two-wire smoke detection support, making it a practical choice for small to mid-size commercial and institutional buildings where zone-level identification meets the fire protection requirements.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":51326476157112,"sku":"PFC-6006-R","price":535.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/9110\/4952\/files\/ScreenShot2025-06-03at7.48.28AM.png?v=1748962114","url":"https:\/\/islandelectricalsupply.com\/products\/potter-pfc-6006-conventional-fire-alarm-panel","provider":"Island Electrical Supply","version":"1.0","type":"link"}